An experimental analysis of the Trombe wall temperature fluctuations for high range climate conditions: Influence of ventilation openings and shading devices

Thumbnail Image
Date
2017
Authors
Briga Sá,A
José Boaventura
Lanzinha,JC
Paiva,A
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Despite the studies already developed about Trombe walls, more research work is needed to contribute to the knowledge about their behaviour and optimize it according to the specific characteristics of each climatic region. The ventilation openings and the shading device operation decisively influence the temperatures fluctuation along the system and that impact should be discussed. In this context, a test cell with a classical Trombe wall was submitted to real climatic conditions in a Portuguese city. The effect of ventilation openings and shading devices in the temperatures fluctuation was analysed. The temperatures in the air layer and along the massive wall presented a similar oscillation pattern and exceeded 60 °C without ventilation and shading devices. For this configuration, temperature values at the top of the air layer were always higher than those obtained at the base and a differential of 19 °C was achieved. The temperature fluctuation across the massive wall was not proportional to its thickness due to its heat storage capacity. When the ventilation system was closed and the shading device was not activated, the temperature inside the test cell exceeded the outside temperature value in 9 °C, showing the system ability to store and release heat. © 2016 Elsevier B.V.
Description
Keywords
Citation