Estimation of RF PA non-linearities after cross-correlating power supply current and output voltage

dc.contributor.author Ricardo Veiga en
dc.contributor.author Pedro Manuel Mota en
dc.contributor.author José Machado da Silva en
dc.date.accessioned 2017-11-16T12:45:31Z
dc.date.available 2017-11-16T12:45:31Z
dc.date.issued 2009 en
dc.description.abstract The present paper describes developments carried-out on estimating 1 dB compression and third order intercept points after the cross-correlation between power supply dynamic current and output voltage of radio frequency power amplifier. The underlining theory and a circuit that allows implementing this measurement on-chip are presented. Simulation results, including the analysis of optimum stimuli amplitudes and the Monte Carlo analysis to circuits' process variations are presented. These show that good accuracy can be obtained with relatively simple measurement conditions. en
dc.identifier.uri http://repositorio.inesctec.pt/handle/123456789/1738
dc.language eng en
dc.relation 1600 en
dc.rights info:eu-repo/semantics/openAccess en
dc.title Estimation of RF PA non-linearities after cross-correlating power supply current and output voltage en
dc.type conferenceObject en
dc.type Publication en
Files