Giant Displacement Sensitivity Using Push-Pull Method in Interferometry

No Thumbnail Available
Date
2021
Authors
Paulo Robalinho
Orlando Frazão
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
<jats:p>We present a giant sensitivity displacement sensor combining the push-pull method and enhanced Vernier effect. The displacement sensor consists in two interferometers that are composed by two cleaved standard optical fibers coupled by a 3 dB coupler and combined with a double-sided mirror. The push pull-method is applied to the mirror creating a symmetrical change to the length of each interferometer. Furthermore, we demonstrate that the Vernier effect has a maximum sensitivity of two-fold that obtained with a single interferometer. The combination of the push-pull method and the Vernier effect in the displacement sensors allows a sensitivity of 60 ± 1 nm/µm when compared with a single interferometer working in the same free spectral range. In addition, exploring the maximum performance of the displacement sensors, a sensitivity of 254 ± 6 nm/µm is achieved, presenting a M-factor of 1071 and MVernier of 1.9 corresponding to a resolution of 79 pm. This new solution allows the implementation of giant-sensitive displacement measurement for a wide range of applications.</jats:p>
Description
Keywords
Citation