Fabry-Perot cavity based on polymer FBG as refractive index sensor
Fabry-Perot cavity based on polymer FBG as refractive index sensor
dc.contributor.author | Ferreira,MFS | en |
dc.contributor.author | Statkiewiez Barabach,G | en |
dc.contributor.author | Kowal,D | en |
dc.contributor.author | Mergo,P | en |
dc.contributor.author | Urbanczyk,W | en |
dc.contributor.author | Orlando Frazão | en |
dc.date.accessioned | 2018-01-23T11:31:38Z | |
dc.date.available | 2018-01-23T11:31:38Z | |
dc.date.issued | 2017 | en |
dc.description.abstract | The use of a polymer fiber as a refractive index sensor is proposed. A fiber Bragg grating is inscribed near the fiber tip and the fiber is cut shorter thus creating a Fabry-Perot cavity. The reflections between the fiber Bragg grating and the fiber end-face create a Fabry-Perot interferometer. The sensor was characterized to refractive index changes at constant temperature and to temperature at constant refractive index using a fast Fourier transform analysis of the interference signal. The sensor revealed a sensitivity of-1. 94 RIU-1 with a resolution of lx10(-3)RITJ and low sensitivity to temperature, with a cross sensitivity to temperature of 3. 6x10(-4)RIU/degrees C. | en |
dc.identifier.uri | http://repositorio.inesctec.pt/handle/123456789/7236 | |
dc.identifier.uri | http://dx.doi.org/10.1016/j.optcom.2017.03.011 | en |
dc.language | eng | en |
dc.relation | 4061 | en |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.title | Fabry-Perot cavity based on polymer FBG as refractive index sensor | en |
dc.type | article | en |
dc.type | Publication | en |
Files